Abstract

This paper deals with the development of basic parameters required to operate a multi-stage counter-current fluidized bed reactor with downcomer illustrating the mechanism of gas–solid contacting in the system. In addition, the reactor was operated in continuous regime for two phase system over a wide range of operating conditions including height of the downcomer to determine the pressure drop due to the solids in the reactor. The data was generated under steady and stable operation of the column without flooding. Based on the data an empirical correlation have been developed for predicting the pressure drop in the system. The result of this study has great industrial importance for scale-up, design and steady operation of a multi-stage fluidized bed reactor for control of gaseous pollutants. The fluidizing gas was air and the solid phase was lime.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.