Abstract

Experiments have been performed to investigate the cooling performance of triangular folded fin heat sinks made of 6000 series aluminum in a duct flow. The dimension of the triangular folded fin heat sink is 70mm in width and 92 mm in length with an 8-mm-thick base plate. The fin height is varied from 19 to 36 mm and the fin pitch from 5.0 to 9.0 mm. The duct air velocity is in the range of 1.0 to 5.0 m/s and the corresponding Reynolds number based on the hydraulic diameter is varied from 212 to 1974. The experimental results show that the cooling performance of triangular folded fin heat sink is influenced by the fin pitch, the Reynolds number, and the fin height. It increases substantially as the fin pitch decreases and the Reynolds number and the fin height increase. By compiling the experimental data, the heat transfer and the friction factor correlations with plusmn6.5% and plusmn20% accuracy, respectively, are provided for effective design of triangular folded fin heat sinks

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.