Abstract

An experimental investigation has been carried out to study the enhancement in heat transfer coefficient by coiled wire inserts during heating of engine oil inside a horizontal tube. The test-section was a double-pipe counter-flow heat exchanger. The engine oil flowed inside the internal copper tube, while saturated steam, used for heating the oil, flowed in the annulus. First of all, the data were acquired for the heating of engine oil while flowing in the plain tube. Later, seven coiled wires having pitches of 12–69 mm and wire diameters of 2.0 mm and 3.5 mm were put one by one in the oil-side of test-section. The effects of Reynolds number and coiled wire geometry on the heat transfer augmentation and fanning friction factor were studied. Finally, two empirical correlations have been developed for predicting the heat transfer enhancement of these coiled wire inserts. These correlations predict the experimental Nusselt number in an error band of ±20 percent.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.