Abstract

The objective of this study is to determine the effect of water temperature and volume flow rate on the pressure drop across a U type evacuated tubular collector. The findings are expected to be useful for pump selection and to determine the pumping power required for operating an Evacuated tubular collector based solar thermal plant. A detailed mathematical model is developed, utilizing correlations found in literature. An experimental investigation is carried out on an experimental setup consisting of Evacuated tubular solar collector combined with instrumentation. The developed mathematical model was simulated, and the results were validated with the data obtained from the experimental investigation within the minimum acceptable normalized root-mean-squared error. Results showed that the pressure drop across the setup reduces as the water temperature increases. The pressure drop also exhibited a non-linear function of the volume flow rate of water and hence at higher flow rates, minor changes in volume flow rate produce a larger pressure drop across the setup.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.