Abstract

The dynamics of working gas pressure changes in the plasma focus (PF) chambers were studied by using the chamber with a built-in manometer as part of the ING-102 neutron generator (2.5 MeV neutron yield 106÷107 neutrons/pulse). Investigations were carried out during high-voltage training and neutron emission operation mode. The studies were executed while filling the chamber with various gas mixtures. For operation with a deuterium-tritium mixture, a sealed-off chamber with a built-in gas generator was used. After the primary filling of the PF chambers with a gas mixture, there is a systematic decrease in pressure by Δp = (5 ÷ 50) ·10−3 Torr (∼0,7 ÷ 7 Pa) after each shot of the chamber.The change in the shape of breakdown curves Ubr(p) in the interelectrode gap of the chamber after each series of shots was studied. That made it possible to assess the optimal number of shots during high-voltage training of the PF chamber.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.