A 58-year-old man, in whom the cochlear implant (CI) had been inserted into the left ear, had right middle-ear cancer. The CI was removed immediately before receiving subtotal removal of right temporal bone. Four months later, the CI was again inserted in his left cochlea. Because of obliterated scala tympani, the 22 active electrodes of the CI were placed into the scala vestibuli. After the surgery, the patient complained that he experienced rotary vertigo and "jumbling of vertical direction" of objects on walking. Using rotation test, we evaluated vestibular function of remaining left ear. Numerous horizontal nystagmus beats were induced during earth-vertical axis rotation, whereas vertical downbeat nystagmus was scarcely induced during off-vertical axis rotation. The horizontal vestibulo-ocular reflex (VOR) was almost normally induced by sinusoidal stimulation at 0.8Hz. These data suggest that the scala vestibuli insertion of CI would be not so invasive against the lateral semicircular canal.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.