Abstract

The preservation of arsenic species in water samples is an indispensable method to avoid their changes during storage, if it is not possible to analyse them immediately. The aim of this investigation was to demonstrate the limitations of the suggested method by using phosphoric acid as a preservation agent. The samples remain stable for 3 months, even if they show evidence of high concentrations of iron or manganese. Critical is an increasing pH > 3. Theoretically, a precipitation of strengite (Fe 3(PO 4) 2) could occur, which should be avoided. Phosphoric acid with a final concentration of 10 mM is recommended as a preservation agent, combined with keeping the samples cool (6 °C) and dark. Filtration of samples before preservation may be carried out with respect to the analytical aim to distinguish between the total and soluble fraction (without colloids). It was shown that filtered and non-filtered samples can be preserved by utilising the above mentioned scheme.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call