Abstract

Non-recurrent laryngeal nerve (NRLN) is an anatomic variation seen in about 0.52-0.7% patients, generally on right side. It exits the vagus nerve having a direct route to the larynx, unlike usual recurrent laryngeal nerve, supplying intrinsic laryngeal muscles except cricothyroid. It is sited over left side on extremely rare occasions, that is, 0.04% of the cases. Some cases of NRLN co-exists with aberrant right subclavian artery which courses behind the esophagus, also known as 'arteria lusoria'. Here we present a case of 60-years old patient, diagnosed as goiter presented to us in june 2023 at the department of head and neck surgery at a tertiary care setup of Karachi Pakistan. Intra-operatively, non-recurrent nerve was encountered, whose association was found with arteria lusoria, observed in pre-operative CT-scan. The nerve was saved and no post-operative complications were seen in patient. The association of arteria lusoria in this case emphasize its importance in predicting NRLN via pre-operative imaging techniques which can prevent its injury intra-operatively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.