Abstract

The PLS-II, the upgraded PLS (Pohang Light Source), has been providing users with photon beams in the top-up mode since March 2013. The requirements for the PLS-II linac to achieve the top-up injection are very demanding because it is a full energy injector with a very limited energy margin. One of the requirements is to ensure high injection efficiency in order to minimize the beam loss at the storage ring injection point and the experimental hall during injection because loss leads to a high radiation level in the experimental hall. The energy stability and energy spread of the accelerated electron beam are fundamental parameters to monitor and manage for high injection efficiency. An energy feedback system consisting of a stripline-type beam position monitor and the last klystron was implemented. To diagnose the injected beam’s energy and energy spread in real time during top-up mode injection, we installed an optical transition radiation (OTR) monitor system upstream of the beam transport line (BTL) after the first bending magnet. The energy and the energy spread ranges can be controlled with a horizontal slit installed after the OTR monitor. The vertical beam size of the accelerated beam must be decreased for efficient injection because the electron beam is injected into the storage ring with many in-vacuum undulators of small gaps. For this purpose, two vertical slits were installed in the BTL region. We will describe mainly those instruments closely related to top-up operation, though other beam diagnostic instruments have been used since PLS.