Abstract

Present results on neutrinoless double beta decay of 130Te obtained with an array of 20 cryogenic detectors are presented. The setup consists of 20 crystals of tellurium oxide of 340 g each, corresponding to the largest presently operating cryogenic mass. Combining the results of the few runs obtained with the same array, corresponding to 1.5 kg yr, a limit on neutrinoless double beta decay half-life of 9.5×10 22 yr (90% CL) has been obtained. On the basis of the results obtained with the MI-BETA experiment, we propose a construction of a 42 kg array of 56 TeO 2 bolometers (CUORICINO project) to extend the sensitivity of the present experiment, and as a first test for CUORE. Thanks to an innovative technique of vibration reduction and despite the high mass (750 g instead of the 340 g of the presently running detectors) we reached an energy resolution of 3.9 keV FWHM at 2615 keV decreasing to 1.4 keV at low energies.