Abstract

Preparative counter-current chromatography (CCC) purification of valrubicin (AD-32) from crude synthetic drug has been successfully performed for the first time using upright coil planet centrifuge with four multilayer coils connected in series with 1600 ml capacity. The two-phase system used was composed of light petroleum (bp 60–90 °C)–ethyl acetate–tetrachloromethane–methanol–water at an optimized volume ratio of 1:1:8:6:1. Target compound (1.2 g) with a purity of 99.88% was obtained from 1.5 g of crude synthetic drug with a purity 95.49% based on HPLC peak area percentage. Identification of the target compound was performed by electrospray ionization mass spectrometry, one- and two-dimensional nuclear magnetic resonance.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.