Abstract

New Ti-based and Zr-based metallic wires for the future application as biomaterials were developed by arc-melting type melt-extraction method. Zr-based metallic glass wire, -Ti type Ti-Zr binary wire and -Ti type Ti-Nb-Ta-Zr (TNTZ) wire show high tensile strength and good vending ductility. Zr-based metallic glass wire shows extremely high tensile strength over 1GPa and large elastic strain limit reached approximately 2%. Ti-Zr binary alloy shows high wire-shape forming tendency during melt-extraction, and high Ti concentration Ti90Zr10 alloy wire was obtained. TNTZ wire shows superior bending ductility and full ductility is achieved.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.