Abstract

The preparation conditions and purification reaction mechanism for H2–HF treatment of molten FLiNaK salt were investigated. The optimal process conditions for preparation of high-purity molten FLiNaK salt were obtained. They are purification temperature of 650°C, liquid height of 0.9m, purification time of 48h, flow ratio of H2/HF=10, flow volume magnitude of 800mL/min, and reaction pressure of 0MPa. The oxygen content of the prepared molten salt was around 80ppm, corrosion impurity elements (Cr, Fe, and Ni) were less than 20ppm, and the S and P contents were below 5ppm. The quality of FLiNaK molten salt prepared by this hydrofluorination process is better than that obtained by adding NH4HF2 as a fluorinating reagent.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call