Abstract

The (37MBq) 99mTc-MIBI complex samples were prepared due to ultrasound irradiation technique or boiled water bath method as a standard method. The qualitative and quantitative studies have been performed. The accumulation of 99mTc-MIBI complexes prepared by two above mentioned modalities were approximately 3 ± 0.1 % in the rats’ heart. The ultrasound irradiation technique is recommended to prepared 99mTc-MIBI complex in efficiently amount. Our approach can potentially reduce medical risk to the patient by avoiding any delay in acute therapy particularly for myocardial infarction patients.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.