Abstract
Abstract2‐chlorobenzoyl ferrocene, was synthesized and used to construct a modified ZnO‐CuO nanoplates modified carbon paste electrode. The electrooxidation of captopril at the surface of the modified electrode was studied. Under the optimized conditions, the square wave voltammetric (SWV) peak current of captopril increased linearly with captopril concentration in the range of 5.0×10−7 to 9.0×10−4 M and detection limit of 90.0 nM was obtained for captopril. The diffusion coefficient and kinetic parameters (such as electron transfer coefficient and the heterogeneous rate constant) for captopril oxidation were also determined. The prepared modified electrode exhibits a very good resolution between the voltammetric peaks of captopril and tryptophan which makes it suitable for the detection of captopril in the presence of tryptophan in real samples.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.