Abstract

In order to investigate and predict effects of preparation parameters on wear mass loss of Ni-SiC composite coatings, Ni coatings and Ni-SiC composite coatings were prepared on steel substrates by electrodeposition process. The results showed that the contents of SiC particles increased with density of pulse current and on-duty ratio of pulse current increasing. The predictive curves of wear mass losses predicted by ANN had the similar shapes with the measured curve, and the maximum error was 9.7%. When the current density was between 30 A/dm2 and 50 A/dm2, the wear losses of Ni coatings and Ni-SiC coatings decreased with the increase of current density. SiC particles in a composite coating electrodeposited by ultrasonic parameters were much greater in number and were dispersed homogeneously in the deposit, and the Ni-SiC composite coating exhibited a dense structure.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.