Abstract

Zr:W:Si. The optimum gel was prepared using the molar ratio 1:1:7 at pH 8. The ZrSiW gel was investigated by FTIR, XRD, thermal analysis (TGA and DTA), FESEM, XRF, and NAA. Then, XRF and NAA techniques were used to estimate the proportion of the constituents of the gel according to the molecular formula [ZrO2(Si(WO4)2)16H2O]. 188W/188Re generator was prepared based on the selected ZrSi188W gel, which gives the highest tungsten content (393.3 mg W/g gel) with 75 ± 3% elution yield of 188Re. Quality control was studied on the 188Re to make sure its validity for clinical applications.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.