Abstract
Micronized Coenzyme Q10 (CoQ10) is prepared with a rapid expansion of supercritical solution (RESS) process, which does not employ toxic organic solvent. Four factors, namely extraction pressure, extraction temperature, nozzle diameter and precipitation temperature are optimized by a four-level orthogonal array design. The optimum micronization conditions are determined as follows: extraction pressure 25 Mpa, extraction temperature 40°C, nozzle diameter 200 μm, and precipitation temperature 25°C. Under the optimum conditions, micronized CoQ10 with a MPS of 147.9±27.3 nm is obtained. The micronized CoQ10 obtained was characterized by High performance liquid chromatography-mass spectrometry (LC–MS) and High performance liquid chromatography (HPLC) analyses. The results showed that RESS micronization process does not induce degradation of CoQ10 and the obtained CoQ10 particles have higher dissolution rate and solubility compared with unprocessed CoQ10 powder.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.