Abstract

Sternal contact of aortic aneurysms in redo operations may require specific techniques to safely control bleeding during sternotomy and surgical dissection. This is the first report on the preoperative use of an inflatable balloon to prevent massive hemorrhage by inserting the balloon--a procedure performed in the cardiac catheterization laboratory--before rethoracotomy. A false ascending aortic aneurysm was successfully sealed by transaortic wire-guided balloon placement from the iliac artery. Gentle traction on the inflated balloon catheter, which was placed inside the false aneurysm, effectively sealed the entrance to the aneurysm. A straightforward median redo sternotomy procedure was subsequently performed without blood loss from the unavoidably opened aneurysm. My colleagues and I propose this technique for aneurysms of mycotic or anastomotic origin, which have an anatomically distinct entry channel.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.