Abstract

Objective: The aims of this study were as follows: (1) to evaluate Doppler ultrasonography in assessing hand collateral circulation; (2) to define the criteria for an abnormal Doppler ultrasonography dynamic test result; and (3) to validate the modified Allen test. Methods: The hand circulation of 71 patients scheduled for coronary artery bypass grafting was assessed by means of the Allen test and Doppler ultrasonography. The flow in the superficial palmar branch of the radial artery, the ulnar artery, and the dorsal digital thumb artery with and without radial artery compression were recorded. Flow patterns in the superficial palmar branch of the radial artery, the ulnar artery, and the dorsal digital thumb artery with radial artery compression were categorized into 4 groups: (1) no flow; (2) decreased flow; (3) reversed flow; and (4) increased flow. Results: Among the 71 hands, 4 (5.6%) had an abnormal Allen test result (>10 seconds). Seven (10.6%) of 66 superficial palmar branches of the radial artery, 3 (4.2%) of 71 ulnar arteries, and 2 (2.8%) of 71 dorsal digital thumb arteries showed no flow with radial artery compression, as measured by Doppler ultrasonography. There were significant differences among the 4 groups (superficial palmar branch of the radial artery: F = 7.0, P <.001; ulnar artery: F = 13.1, P <.001; and dorsal digital thumb artery: F = 8.4, P <.001) for the Allen test. Pairwise comparisons showed that when subjected to an Allen test, category 1 patients (no flow) had significantly longer recovery times compared with the other groups (P <.02 in all cases) for the superficial palmar branch of the radial artery, the ulnar artery, and the dorsal digital thumb artery. Conclusion: Absence of flow in the dorsal digital thumb artery with radial artery compression is considered an absolute contraindication to radial artery harvesting. An increased recovery time with the modified Allen test predicts absence of flow in the dorsal digital thumb artery in Doppler ultrasonographic flow patterns. This demonstrates the validity of the modified Allen test for primary screening. (J Thorac Cardiovasc Surg 2001;121:526-31)

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.