Abstract
AbstractThe design of electric machines is motivated by electromagnetic and mechanical requirements. The magnetic flux is confined and guided by ferrite cores which consist of coated electrical sheets with a thickness of only a few tenths of a millimeter in order to minimize the eddy current losses. This heterogeneous structure causes preload dependent transversal isotropic material properties which affect the fatigue behavior and structural dynamic behavior of the machine. The material constitutive equations are defined by five parameters which must be derived from experimental investigations with respect to compression in the stacking direction. In this paper, a test procedure is introduced to determine the elastic and torsional stiffness as well as the lateral elongation of the stack depending on its preload.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.