Abstract

Abstract. Column-averaged volume mixing ratios of carbon dioxide and methane retrieved from the Greenhouse gases Observing SATellite (GOSAT) Short-Wavelength InfraRed observation (GOSAT SWIR XCO2 and XCH4) were compared with the reference calibrated data obtained by ground-based high-resolution Fourier Transform Spectrometers (g-b FTSs) participating in the Total Carbon Column Observing Network (TCCON). Preliminary results are as follows: the GOSAT SWIR XCO2 and XCH4 (Version 01.xx) are biased low by 8.85 ± 4.75 ppm (2.3 ± 1.2 %) and 20.4 ± 18.9 ppb (1.2 ± 1.1 %), respectively. The standard deviation of the GOSAT SWIR XCO2 and XCH4 is about 1 % (1 σ) after correcting the negative biases of XCO2 and XCH4 by 8.85 ppm and 20.4 ppb, respectively. The latitudinal distributions of zonal means of the GOSAT SWIR XCO2 and XCH4 show similar features to those of the g-b FTS data except for the negative biases in the GOSAT data.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.