Abstract

The paper focused on a self-developed methodology through using sulfur dioxide to deal with high concentration of chromium-containing wastewater. It studied the effects of different pH values, different reaction time, different temperatures and different amounts of sulfur with sulfur dioxide reduction reaction on the chromium-containing wastewater. The results showed that: when the reaction conditions were controlled as follows: the pH values ranged from 2 to 4, the reaction temperature was controlled 40~60°C, the amount of sulfur in theoretical was 1.2 times and the reaction time was 40 min, the hexavalent chromium in the high concentrations of chromium-containing wastewater could be effectively removed.