Abstract

Safety analysis for the design basis accident (DBA) is essential to support DEMO blanket concept design. It is necessary to study the pressure behaviour in the blanket and the connected systems during the loss of coolant accident (LOCA) in a blanket module, as well as the temperature evolution in the coolant flow and the associated structures. For the Helium Cooled Pebble Bed (HCPB) blanket concept (version 2014) three representative accidental sequences of LOCA have been simulated using system code MELCOR 1.8.6 for fusion. The LOCA is identified to be the failure of cooling channels in the stiffening grid, in the FW or in the breeder unit. Simulation results are discussed in this paper.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.