Abstract

In this paper, landfill leachates and vacuum technique were investigated. Conditions for the removal and reclaim of high content ammonia from landfill leachates were studied by vacuum method; the device made on the spot was used to find the optimal experimental procedures. While the operating time was 1.5 hours, the temperature was of 50degC, a vacuum degree was 1.5 m water column, and the highest removal rate for ammonia could be obtained, but the primary ammonia contents of landfill leachates could hardly influence on the efficiency of ammonia removal. In despite of the same condition , adsorption of ammonia by injector was better than by vacuum pump ,that the methods of adsorption are very important for the reclaim of ammonia was demonstrated by the tests. In the work , both the characteristics without adjusting the pH value of 8.5 , and the reclaiming of ammonia, distinguished from others by special quality.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.