Abstract
The alignment tolerance of multipoles on a girder is better than ±30 μm in the storage ring of the High Energy Photon Source (HEPS) which will be the next project at IHEP (Institute of High Energy Physics). It is difficult to meet the precision when only using the traditional optical survey method. In order to achieve this goal, a vibrating wire alignment technique with high precision and sensitivity is considered to be used in this project. This paper presents some preliminary research works about theory, scheme design and achievements.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.