Abstract

Abstract Membrane filtration is commonly applied to reduce dissolved organic carbon (DOC) to control the formation of trihalomethanes (THMs); however, high levels of DOC can cause severe fouling of reverse osmosis membranes. The integrated biological and reverse osmosis membrane (IBROM) process is a combination of biological filters and reverse osmosis membranes. The IBROM process claims to remove biodegradable dissolved organic carbon (BDOC), which apparently should result in reduced membrane fouling. The goal of this research was to conduct a preliminary investigation into the claims of the IBROM system, using water collected from the Herbert water treatment plant (Saskatchewan). The plant is utilizing the IBROM for the treatment of a dugout and groundwater blend (DOC of 17.5–22.7 mg/L). The results demonstrated that BDOC concentrations did not change significantly throughout the plant. Optimized laboratory-scale coagulation with polyaluminium chlorohydrate achieved 58% removal of BDOC. Oxidation with permanganate increased the concentration of BDOC (from 5.7 to 8.8 mg/L). Overall, BDOC was effectively removed by optimized coagulation rather than the IBROM system. Moreover, the results show an inverse relationship between BDOC and THMs formation potential (THMFP) in both coagulated and oxidized water. For all concentrations, more biodegradable DOC had less tendency to form THMs based on the lower THMFP.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call