Abstract

In this paper, some results are presented from experiments concerning partial discharge (PD) behaviour of epoxy resin samples having 3 wt% nano- and 3 wt% micro-fillers, as well as epoxy samples having 3wt%and1wt% nanoparticles. The nano- and micro-fillers were TiO2 (titania). The main idea is to see whether a sample with PD at its inception voltage, still presents some tendency to charging effects below inception. An effort is being made to relate the present work with previous publications on the same main idea, as well as to previous research performed recently at Xian Jiaotong University, State Key Laboratory of Electrical Insulation and Power Equipment. It is indicated that with the samples investigated, although on some occasions random charging phenomena were observed below the inception voltage, it was not noted the same behaviour as with pure epoxy samples. Finally, a discussion ensues as to the definitions of the phenomena taking place below inception voltage.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.