Abstract
We evaluated the Precision Xtra™ ketometer as part of a larger study categorizing fasting status of free-ranging Steller sea lion (Eumetopias jubatus; SSL) pups which necessitated the identification of plasma β-hydroxybutyrate concentrations ([β-HBA]) around a threshold of <0.3 and ≥0.3mmol/l. Whole blood samples mixed with sodium heparin (NaHep) or ethylenediaminetetraacetic acid liquid anticoagulants were tested <10minutes after collection (n = 14; triplicate technical replicates). Plasma (stored at -80°C, NaHep, Thaw1) measured via our laboratory's Reference Assay (Sigma Aldrich, St. Louis, MO, Kit #MAK041) served as the standard [β-HBA] for ketometer comparisons. Our observed β-HBA range (0.0-1.6mmol/l), consistent with published [β-HBA] of free-ranging Otariid pups, represented the lower 20% of the ketometer's range (0.0-8.0mmol/l). The maximal coefficient of variation (%CV) of ketometer technical replicates was 9.1% (NaHep, whole blood). The majority of ketometer technical replicate sets (84%, including all matrices, anticoagulants and thawings) were identical (CV = 0%). We found linear relationships and agreement of ketometer [β-HBA] between whole blood preserved with different anticoagulants and between whole blood and plasma (Thaw1) measurements. The ketometer produced results with linearity to the Reference Assay for both whole blood and plasma (Thaw1). We identified a non-linear relationship between plasma at Thaw1 and Thaw2 (tested four months apart, NaHep), as only samples with higher SSL [β-HBA] decreased in concentration, and all others remained the same. With respect to categorizing SSL pup fasting in our larger study, the ketometer's %Accuracy, %Sensitivity and %Specificity for samples with Reference Assay β-HBA <0.2 and >0.4mmol/l were 100%. We adopted a modified procedure: plasma samples with mean ketometer concentrations ±0.1mmol/l of 0.3mmol/l β-HBA were re-evaluated using the Reference Assay, improving measurement precision from tenths (ketometer) to thousandths (assay) mmol/l. The Precision Xtra™ ketometer was valuable to our application over the range of [β-HBA] observed in SSL pup plasma and whole blood samples.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.