Abstract

BackgroundAcetabular reinforcement devices (ARDs) are frequently used as load-sharing devices to allow allograft incorporation in revision hip arthroplasty with massive acetabular bone loss. The key to a successful reconstruction is robust fixation of the device to the host acetabulum. Interlocking fixation is expected to improve the initial stability of the postoperative construct. However, all commercially available ARDs are designed with non-locking fixation. This study investigates the efficacy of standard ARDs modified with locking screw mechanisms for improving stability in acetabular reconstruction.MethodsThree types of ARDs were examined to evaluate the postoperative compression and angular stability: i) standard commercial ARDs, ii) standard ARDs modified with monoaxial and iii) standard ARDs modified with polyaxial locking screw mechanisms. All ARDs were implanted into osteomized synthetic pelvis with pelvic discontinuity. Axial compression and torsion tests were then performed using a servohydraulic material testing machine that measured load (angle) versus displacement (torque). Initial stability was compared among the groups.ResultsEquipping ARDs with interlocking mechanisms effectively improved the initial stability at the device/bone interface compared to standard non-locked ARDs. In both compression and torsion experiments, the monoaxial interlocking construct demonstrated the highest construct stiffness (672.6 ± 84.1 N/mm in compression and 13.3 ± 1.0 N·m/degree in torsion), whereas the non-locked construct had the lowest construct stiffness (381.4 ± 117.2 N/mm in compression and 6.9 ± 2.1 N·m/degree in torsion) (P < 0.05).ConclusionsOur study demonstrates the potential benefit of adding a locking mechanism to an ARD. Polyaxial ARDs provide the surgeon with more flexibility in placing the screws at the cost of reduced mechanical performance. This in vitro study provides a preliminary evaluation of biomechanical performance for ARDs with or without interlocking mechanisms, actual clinical trial deserves to be further investigated in future studies.

Highlights

  • Acetabular reconstruction for patients with massive acetabular defects remains one of the most difficult problems in revision total hip arthroplasty (THA) [1,2]

  • Equipping Acetabular reinforcement devices (ARDs) with interlocking mechanisms effectively improved the initial stability at the device/bone interface compared to standard non-locked ARDs

  • Our study demonstrates the potential benefit of adding a locking mechanism to an ARD

Read more

Summary

Introduction

Acetabular reconstruction for patients with massive acetabular defects remains one of the most difficult problems in revision total hip arthroplasty (THA) [1,2]. An acetabular reinforcement device (ARD, antiprotrusio cage) is frequently used as a load-sharing device to provide initial stability for the reconstruction and to allow the incorporation of the allograft into the host pelvis without stress [3] (Fig. 1). The key to a successful reconstruction is robust fixation of the device to the host acetabulum, which is often very deficient in the revision setting. Acetabular reinforcement devices (ARDs) are frequently used as load-sharing devices to allow allograft incorporation in revision hip arthroplasty with massive acetabular bone loss. The key to a successful reconstruction is robust fixation of the device to the host acetabulum. This study investigates the efficacy of standard ARDs modified with locking screw mechanisms for improving stability in acetabular reconstruction

Methods
Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.