Abstract

To summarize the surgical learning curve and preliminary operative experience of dual-robotic navigated minimally invasive treatment on pelvic fractures by TiRobot and Artis Zeego. Between July 2019 and February 2021, 90 patients with pelvic fractures were treated with dual-robotic navigated minimally invasive surgery by TiRobot and Artis Zeego. There were 64 males and 26 females, with an average age of 46.5 years (range, 13-78 years). Body mass index was 14.67-32.66 kg/m 2 (mean, 23.61 kg/m 2). Causes of injuries included traffic accident in 43 cases, falling from height in 37 cases, low-energy injuries such as flat falls in 10 cases. The interval between injury and surgery was 1-36 days (mean, 7.3 days). According to the location of the implanted screws, the patients were divided into sacroiliac screw group ( n=33), acetabular screw group (acetabulum anterior/posterior column, n=24), composite screws group (sacroiliac and acetabulum anterior/posterior column, n=33). According to the screw implantation time and accuracy, the surgical learning curve was plotted, and the differences in the relevant indicators between learning stage and skilled stage were compared. All 90 patients successfully completed the operation, the intraoperative bleeding volume was 5-200 mL (median, 20 mL). There was no vascular or nerve injury. All incisions healed by first intention. The screw implantation time ranged from 7.5 to 33.0 minutes (mean, 18.92 minutes), and the screw implantation accuracy ranged from 1.1 to 1.8 mm (mean, 1.56 mm). According to the learning curve, the practice stage of 3 groups was reached after 7, 10, and 11 cases, respectively. With the accumulation of surgical experience, the screw implantation time had a significant downward trend. Compared with the learning stage, the screw implantation time on skilled stage in 3 groups significantly shortened ( P<0.05), but the difference in the screw implantation accuracy was not significant ( P>0.05). TiRobot and Artis Zeego assisted pelvic fracture surgery is safe and efficient, which helps the surgeon to quickly master the pelvic channel screw surgery, and the operation time is significantly shortened on the premise of ensuring the implantation accuracy.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call