Abstract
Objective: To explore the preliminary application effect of real-time fluorescence recombinase polymerase amplification (RPA) in the detection of Candida albicans. Methods: (1) Candida albicans standard strain and negative control bacteria of Pseudomonas aeruginosa, Staphylococcus aureus, Acinetobacter baumannii, Escherichia coli, Candida glabrata standard strains of respectively 1 mL were collected and their DNA were extracted by yeast/bacterial genomic kit. The specificity of polymerase chain reaction (PCR), real-time fluorescent quantitative PCR, and real-time fluorescence RPA in detecting Candida albicans were analyzed. (2) One Candida albicans standard strain and one negative control bacteria of Candida glabrata standard strain were collected, resuscitated, and counted. Candida albicans was diluted 10 times to 1×10(7) to 1×10(1) colony-forming unit (CFU)/mL. The DNA of the two bacteria were extracted as experiment (1). The sensitivity of PCR, real-time fluorescent quantitative PCR, and real-time fluorescence RPA in detecting Candida albicans were analyzed. The number of cycles for amplification curve to reach the threshold in real-time fluorescent quantitative PCR, and time of appearance of specific amplification curve in real-time fluorescence RPA were recorded and compared with the results in PCR. The detection limit and rate of the above-mentioned 3 methods in detecting Candida albicans were analyzed, and the correlation between concentration of Candida albicans in real-time fluorescence RPA and detection time was analyzed. (3) One standard strain of Candida albicans was collected, and the DNA was extracted as experiment (1) and detected by PCR, real-time fluorescent quantitative PCR, and real-time fluorescence RPA. The total detection time of the above-mentioned 3 methods was recorded, respectively. (4) The DNA of 31 clinical samples of suspected Candida albicans infection and 1 clinical sample of Candida albicans collected from cotton swab were extracted, PCR and real-time fluorescence RPA were carried out, and the positive detection rates of the above-mentioned methods were calculated. The DNA of the clinical samples with positive results in both PCR and real-time fluorescence RPA were extracted by yeast/bacterial genomic kit, chelex-100 boiling method, and repeatedly freeze-thawing with liquid nitrogen method, and real-time fluorescence RPA and PCR were carried out. The negative control bacteria was Candida glabrata in real-time fluorescence RPA, while negative control bacteria in PCR were the same as experiment (1). The positive results in PCR and real-time fluorescence RPA were observed and time for amplification curve to reach the fluorescence threshold in real-time fluorescence RPA was recorded, respectively. Data were processed with linear correlation analysis and t test. Results: (1) Three methods showed positive results in detecting standard strain of Candida albicans, and none of the 5 negative control bacteria showed positive results. (2) As the concentration of bacterial solution of Candida albicans decreased, the number of cycles for the amplification curve to reach the threshold increased in real-time fluorescent quantitative PCR, the time for appearance of specific amplification curve prolonged in real-time fluorescence RPA, and brightness of the gel strip weakened in PCR. None of the negative control bacteria in the above-mentioned 3 detection methods showed corresponding positive results. The detection limit of Candida albicans in real-time fluorescence RPA, PCR, and real-time fluorescent quantitative PCR was 1×10(1) CFU/mL. There was a significant negative correlation between the concentration of Candida albicans and the detection time in real-time fluorescence RPA (r=-0.95, P<0.01). The positive detection rates of PCR and real-time fluorescent quantitative PCR for Candida albicans of 1×10(1) to 1×10(7) CFU/mL were 100%. The positive detection rate of real-time fluorescence RPA for Candida albicans of 1×10(1) CFU/mL was 78%, and the positive detection rate of real-time fluorescence RPA for Candida albicans of 1×10(2) to 1×10(7) CFU/mL was 100%. (3) The total time of PCR, real-time fluorescent quantitative PCR, and real-time fluorescence RPA detection for Candida albicans was 133, 93, and 35 min, respectively. (4) The positive detection rate of real-time fluorescence RPA for 31 clinical samples of suspected Candida albicans infection was 32.26% (10/31), which was slightly lower than 35.48% (11/31) of PCR. Eleven clinical samples showed positive results both in real-time fluorescence RPA and PCR detection. No positive result was observed in the negative control bacteria detected both by real-time fluorescence RPA and PCR. The DNA was extracted by yeast/bacterial genomic extraction kit and chelex-100 boiling method for real-time fluorescence RPA detection. The time for the amplification curve to reach the threshold was (438±13) and (462±12) s, respectively, which was close (t=1.32, P>0.05). The DNA was extracted by repeatedly freeze-thawing with liquid nitrogen method for real-time fluorescence RPA, and the time for the amplification curve to reach the threshold in real-time fluorescence RPA was (584±15) s, which was significantly longer than that in the other 2 methods (t=7.55, 6.39, P<0.01). Conclusions: Real-time fluorescence RPA has advantages of rapid detection, simple operation, high sensitivity, and good specificity in detecting Candida albicans, which is worthy of clinical application.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.