Abstract
For the application to plasma facing component (PFC) in a fusion reactor, joining methods between tungsten (W) and ferritic-martensitic steel (FMS) have been developed and three W/FMS mockups were fabricated by HIP (hot isostatic pressing) joining method. Because the high heat flux test should be performed over the thermal lifetime of the mockup to confirm the integrity of joining technology, test conditions are found by performing a thermal-hydraulic and thermo-mechanical analysis with the conventional codes such as ANSYS-CFX and ANSYS-mechanical, respectively. From the analysis, the heating and the cooling conditions are determined, for 1.0MW/m2 heat flux, to be 30s heating and 30s cooling with given test facility cooling system. And the test cycle number for thermal-fatigue testing is determined to be 2500 cycles because the estimated thermal-lifetime of the mockup is about 2324 cycles from the results of elastic-plastic analysis. The high heat flux test with KoHLT-EB will be performed with these test conditions in the near future.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.