Abstract

Preferential removal of components from mixed material targets and plasma shielding are studied by using inductively coupled plasma-atomic emission spectrometry (ICP-AES) during UV nano-second laser ablation. The ICP emission intensity for Cu and Zn during ablation of brass samples varies versus laser power density. A model using thermal evaporation and inverse Bremsstrahlung processes is presented. The model shows that plasma shielding occurs at approximately 0.3 GW/cm2, in agreement with experimental data for change in the mass ablation rate. The good agreement of model and experimental data suggest that thermal effects are important during nano-second laser ablation for power density less than 0.3 GW/cm2.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.