Cathodic protection (CP) of reinforcing steel has been applied successfully to concrete structures with corrosion damage for more than 25 years. Performance and maintenance data are reported from an inventory of CP systems in The Netherlands installed on about 100 structures between 1987 and 2010. The large majority provides corrosion protection for a long time. Degradation of components and overall systems seems to occur in limited numbers. Failure of components and total systems as a function of age is quantified. On the average, the time until minor repairs of parts is necessary is about 15 years. Global failure of the anode, which necessitates near complete replacement of the system, is rare. Based on the statistical analysis of field data, the cost of maintaining a CP system is predicted using a life cycle cost model.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.