Abstract

“Crystal” guava (Psidium guajava L.) is a climacteric fruit that is generally harvested by farmers based on cultivation experience. In this study, portable 740-1070 nm of near-infrared spectrometer was employed to rapidly predict harvest indices of “crystal” guava, by means of non-contact and non-destructive approach. Samples of guava fruit were collected at days after anthesis (DAS) of 91, 94, 97, and 100. The total number of each sample were 30 fruits. The firmness, soluble solid content, acidity and sugar acid ration were evaluated as quality parameters. Partial least square (PLS) method was utilized for data processing. It was found that Standard Normal Variate (SNV) resulted the best pre-processing for all quality parameters. Performances of best models were demonstrated by coefficient of corraltion (R), standard error of calibration (SEC) and standard error of prediction (SEP), which were respectively 0.88, 6.21, 5.92 for firmness prediction, 0.74, 0.84, 0.79 for soluble solid content prediction, 0.59, 0.19, 0.26 for acidity prediction, and 0.71, 1.21, 1.58 for sugar acid ratio prediction model.

Highlights

Read more

Summary

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.