Abstract

BackgroundThe effect of right ventricular (RV) leads on tricuspid valve has been already raised concerns, especially in terms of prognostic implication. For such assessment, three-dimensional transthoracic echocardiography (3D-TTE) has been used previously but there was no data on the use of post-procedural fluoroscopy in the literature.MethodsWe prospectively enrolled 59 patients who underwent clinically indicated placement of pacemaker or implantable cardioverter defibrillator (ICD). Vena contracta (VC) and tricuspid regurgitation (TR) severity were measured using two-dimensional transthoracic echocardiography (2D-TTE) at baseline. Follow up 3D-TTE was performed 6 months after device implantation to assess TR severity and RV lead location.ResultsLead placement position in TV was defined in 51 cases.TR VC was increased after the lead placement, compared to the baseline study (VC: 3.86 ± 2.32 vs 3.18 ± 2.39; p = 0.005), with one grade worsening in TR in 25.4% of cases. The mean changes in VC levels were 1.14 ± 0.67 mm. Among all investigated parameters, VC changes were predicted based on lead placement position only in 3D-TTE (p < 0.001) while the other variables including fluoroscopy parameters were not informative.ConclusionThe RV Lead location examined by 3D-TTE seems to be a valuable parameter to predict the changes in the severity of the tricuspid regurgitation. Fluoroscopy findings did not improve the predictive performance, at least in short term follow up.

Highlights

  • IntroductionIt is still unclear whether the ventricular pacemaker lead can cause or exacerbate tricuspid regurgitation (TR) [4,5,6]

  • Due to prolonged life span of the community,the use of pacemakers and defibrillators is widely expanding, in order to control abnormal heart rhythms and prevent the Poorzand et al Cardiovascular Ultrasound (2021) 19:37[3]

  • The purpose of the current study was to evaluate the effect of right ventricular (RV) lead placement on tricuspid valve, utilizing fluoroscopy in combination with 3D-TTE

Read more

Summary

Introduction

It is still unclear whether the ventricular pacemaker lead can cause or exacerbate TR [4,5,6]. The purpose of the current study was to evaluate the effect of RV lead placement on tricuspid valve, utilizing fluoroscopy in combination with 3D-TTE. The effect of right ventricular (RV) leads on tricuspid valve has been already raised concerns, especially in terms of prognostic implication. For such assessment, three-dimensional transthoracic echocardiography (3D-TTE) has been used previously but there was no data on the use of post-procedural fluoroscopy in the literature.

Objectives
Methods
Results
Conclusion