Abstract

This study aimed to investigate clinical and preintervention optical coherence tomography (OCT) findings to predict irregular protrusion (IRP) immediately after stent implantation.We evaluated 84 lesions treated with cobalt-chromium everolimus-eluting stent (CoCr-EES) from the MECHANISM Elective study. Patients were divided into two groups according to the presence of IRP [IRP: n = 16, non-IRP: n = 68]. Optical coherence tomography images before intervention and immediately after stenting were evaluated with standard qualitative and quantitative OCT analyses.Total cholesterol and the prevalence of ruptured plaque before intervention were significantly higher in the IRP group than in the non-IRP group [199 ± 37 mg/dL versus 176 ± 41 mg/dL; P = 0.022, 31% versus 7%; P = 0.008]. Total lipid length tended to be longer in the IRP group than in the non-IRP group [19.6 ± 9.2 mm versus 15.5 ± 9.3 mm; P = 0.090]. The prevalence of ruptured plaque, and total cholesterol levels were independent predictors of IRP immediately after stenting by multivariate logistic regression analysis [OR: 4.6, 95% confidence interval: 1.01-21.23, P = 0.048, OR: 1.02, 95% confidence interval: 1.00-1.03, P = 0.046]. IRP post-CoCr-EES implantation was completely resolved at follow-up OCT.The prevalence of ruptured plaque before intervention and total cholesterol levels were independent predictors of IRP after CoCr-EES implantation in patients with stable coronary artery disease.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call