Abstract

Abstract Funding Acknowledgements Type of funding sources: None. Background Implantable cardiac defibrillators (ICD’s) are recommended in patients with heart failure with reduced ejection fraction (HFrEF) of nonischemic etiology. Determining patients who are at high risk despite ICD implantation is of clinical value. Methods Between 2009-2019 patients who were implanted ICD due to nonischemic HFrEF were included to the present analysis. Baseline characteristics, laboratory parameters and echocardiographic findings were obtained from the electronic database. The primary outcome was all-cause mortality. Appropriate and inappropriate device therapies were also extracted from the database and was confirmed with patients’ reports. Predictors for long term all-cause mortality was determined by using Cox regression analysis. Results Overall, 1199 patients were screened and 238 were eligible for the analysis. ICD’s were implanted for primary and secondary prevention in 68 (28.6%) and 170 (71.4%) of patients respectively. Multivariate analysis revealed that increased pro-BNP [Hazard ratio (HR): 1.001, 95% Confidence interval (CI): 1.000 – 1.001, p = 0.024] and reduced left ventricle ejection fraction (HR: 0.950, 95% CI: 0.907 – 0.994, p: 0.026) predicted all-cause mortality during long term follow up. Pro-BNP > 425 pg/ml has sensitivity and specificity of 74% for each in predicting all-cause mortality. Conclusion Among patients who were implanted ICD for HFrEF of nonischemic etiology, higher pro-BNP prior to the implantation and lower LVEF predicted all-cause mortality during long term follow up. Table 1Univariate analysisP valueHR (95% CI)Multivariate analysisP valueHR (95% CI)Diabetes mellitus0.0062.587 (1.315 - 5.090)Diabetes mellitus0.1441.837 (0.812 - 4.153)Atrial fibrillation0.0023.080 (1.531 - 6.195)Atrial fibrillation0.1811.738 (0.774 - 3.903)NYHA > 20.0172.394 (1.168 - 4.908)NYHA > 20.2531.642 (0.701 - 3.847)RDW0.0441.191 (1.005 - 1.412)RDW0.6461.046 (0.862 - 1.270)Lymphocytes0.0220.616 (0.408- 0.932)Lymphocytes0.1650.683 (0.399 - 1.170)Blood urea nitrogen0.0381.015 (1.001- 1.030)Blood urea nitrogen0.1521.015 (0.995 - 1.036)Pro-BNP<0.0011.001 (1.000 - 1.001)Pro-BNP0.0241.001 (1.000 - 1.001)Albumin<0.0010.252 (0.143 - 0.444)Albumin0.0790.525 (0.256 - 1.079)Ejection fraction<0.0010.921 (0.885 - 0.959)Ejection fraction0.0260.950 (0.907 - 0.994)LVEDD0.0011.408 (1.017 - 1.079)LVEDD0.1521.078 (0.973 - 1.194)LVESD0.0041.038 (1.012 - 1.065)LVESD0.2890.957 (0.883 - 1.038)Appropriate shock in follow-up0.0102.407 (1.237 - 4.684)Appropriate shock in follow-up0.1561.768 (0.805 - 3.883)Univariate and multivariate Cox regression analyses for long-term mortality after ICD implantation Abstract Figure 1

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.