Abstract
BackgroundThe superiorities in proximal facet joint protection of robot-assisted (RA) pedicle screw placement and screw implantation via the cortical bone trajectory (CBT) have rarely been compared. Moreover, findings on the screw accuracy of both techniques are inconsistent. Therefore, we analyzed the screw accuracy and incidence of facet joint violation (FJV) of RA and CBT screw insertion in the same study and compared them with those of conventional pedicle screw (PS) insertion. The possible factors affecting screw accuracy and FJV were also analyzed.MethodsA total of 166 patients with lumbar degenerative diseases requiring posterior L4-5 fusion were retrospectively included and divided into the RA, PS, and CBT groups from March 2019 to December 2021. The grades of intrapedicular accuracy and superior FJV were evaluated according to the Gertzbin–Robbins scale and the Babu scale based on postoperative CT. Univariable and multivariable analyses were conducted to assess the possible risk factors associated with intrapedicular accuracy and superior FJV.ResultsThe rates of optimal screw insertion in the RA, PS, and CBT groups were 87.3%, 81.3%, and 76.5%, respectively. The difference between the RA and CBT groups was statistically significant (P = 0.004). Superior FJVs occurred in 28.2% of screws in RA, 45.0% in PS, and 21.6% in CBT. The RA and CBT groups had fewer superior FJVs than the PS group (P = 0.008 and P < 0.001, respectively), and no significant difference was observed between the RA and CBT groups (P = 0.267). Multivariable analysis revealed that the CBT technique was an independent risk factor for intrapedicular accuracy. Furthermore, older age, the conventional PS technique and a smaller facet angle were independently associated with the incidence of superior FJVs.ConclusionsThe RA and CBT techniques were associated with fewer proximal FJVs than the PS technique. The RA technique showed a higher rate of intrapedicular accuracy than the CBT technique. The CBT technique was independently associated with screw inaccuracy. Older age, conventional PS technique and coronal orientation of the facet join were independent risk factors for superior FJV.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.