Abstract

The study sought to analyze the risk of ventricular tachyarrhythmia (VTA) or death in black and whitesubjects implanted with implantable cardioverter-defibrillators (ICDs) or defibrillator and combined cardiac resynchronization therapy (CRT-D) in the MADIT-CRT (Multicenter Automatic Defibrillator Implantation with Cardiac Resynchronization Therapy) trial. There are limited data on ethnic differences in the risk for VTA in mildly symptomatic heart failure patients with left ventricular dysfunction. The risk for first VTA (≥180 beats/min) or death was evaluated in black (n= 139) versus white (n= 1,638) patients enrolled in the MADIT-CRT trial using Kaplan-Meier survival analyses and Cox proportional hazards regression models after adjustment for relevant clinical covariates. Multivariate analysis was used to identify race-specific risk factors for VTA. At 4 years of follow-up, the cumulative probability for a first VTA or death was significantly higher among black patients (42%) as compared with whites (34%; log-rank p value for the overall difference during follow-up= 0.01). Multivariate analysis confirmed significantly higher risk of VTA or death (hazard ratio: 1.60; 95% confidence interval: 1.18 to 2.17; p= 0.002), and higher risk of VTA alone (hazard ratio: 1.71; 95% confidence interval: 1.22 to 2.41; p= 0.002) in blacks compared to whites. The findings were similar in both ICD and CRT-D implanted patients, with no significant race-to-treatment-interaction (interaction p values >0.05). Independent risk factors for VTA among blacks included increased systolic blood pressure values and larger cardiac volumes. In the MADIT-CRT trial, black patients had a significantly higher rate of ventricular tachyarrhythmias or death compared to whites, with either an implanted ICD or CRT-D. (MADIT-CRT: Multicenter Automatic Defibrillator Implantation with Cardiac Resynchronization Therapy [MADIT-CRT], NCT00180271; Multicenter Automatic Defibrillator Implantation with Cardiac Resynchronization Therapy Post Approval Registry [MADIT-CRT PAR], NCT01294449; MADIT-CRT LONG-TERM INTERNATIONAL FOLLOW-UP REGISTRY-EUROPE, NCT02060110).

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.