Abstract
To understand whether the preoperative morphology of the posterior corneal surface influences the rate of re-bubbling after Descemet membrane endothelial keratoplasty (DMEK). After retrospectively analyzing the medical records of patients undergoing DMEK, in this multicentric cross-sectional study, we performed a binomial logistic regression analysis to assess significant predictors of re-bubbling and re-transplantation after surgery. Analyzed parameters included the preoperative diagnosis, anterior and posterior surface K1/K2, central corneal thickness, posterior Q value, and other posterior corneal surface parameters evaluated on the elevation maps produced by anterior segment optical coherence tomography. Results were stratified based on the surgeons' experience. We included 202 eyes of 202 patients with a mean age of 69.5 ± 12.4years; 154 eyes were operated by a high-volume surgeon and 48 by one with less experience; 48 eyes (23.8%) underwent 1 re-bubbling and 14(6.9%) 1 re-transplantation. The presence of positive/less-negative posterior corneal irregularities and irregularities with greater absolute height had a significantly higher risk of re-bubbling in both the expert and less expert group (OR = 2.85 and 1.42, OR = 3.22 and 3.01, respectively, p < 0.05), whereas more negative posterior K1 and K2 were significant risk factors only in the former group (OR = 0.67 and 0.55, respectively, p < 0.05). Endothelial decompensation other than Fuchs and pseudophakic bullous keratopathy, more negative posterior Q values and smaller distances between center, and the highest/lowest posterior corneal surface irregularity correlated with an increased risk of graft failure (OR 1.23, 1.21, and 1.29, respectively, p < 0.05). Posterior corneal surface morphology significantly influences the risk of re-bubbling after DMEK.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.