Abstract
In this paper, finite control-set model predictive control of two-level and three-level four-leg voltage source converters (VSCs) is presented. The predictive current control (PCC) and predictive voltage control (PVC) schemes are presented considering grid-connected and standalone distributed generation applications respectively. The discrete-time model of load currents, load voltages, DC-link capacitors voltage and VSC terminal voltages is formulated in terms of four-leg converter switching states. A cost function is defined with the PCC scheme to minimize the error between reference and predicted load currents. Similarly, in PVC scheme, the cost function deals with the minimization of error between reference and predicted load voltages. The balancing of split DC-link capacitors voltage is considered with the three-level four-leg VSCs. The optimal switching states which minimize the cost function are chosen and applied to the four-leg VSC directly without involving linear regulators and modulation stage. The proposed PCC and PVC strategies are verified through simulation results considering single-/three-phase, balanced/unbalanced and linear/nonlinear loads.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.