Abstract

This paper presents the implementation of a predictive control scheme for an indirect matrix converter. The control scheme selects the switching state that minimizes the reactive power and the error in the output currents according to their reference values. This is accomplished by using a prediction horizon of one sample time and a very intuitive control law. Experimental results with a 6.8-kVA indirect matrix converter prototype are provided in order to validate the proposed control scheme. The converter uses standard digital signal processor operating at a sampling frequency of 20 mus. It is shown that the idea of controlling this converter topology with a predictive approach can be implemented simply and input currents with unity power factor and a total harmonic distortion lower than 5% can be obtained.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.