Abstract
AbstractOne of the key components in a renewable energy system such as wind energy generator is a three-phase regenerative PWM converter. This component is nonlinear and time-varying by nature. However, with the classical synchronous frame transformation, the nonlinear model is linearized to obtain a continuous-time state-space model. Based on the linearized model, in this paper, a continuous-time model predictive control system (Laguerre function based) for a three-phase regenerative PWM converter is designed and implemented on a laboratory scaled test-bed that was built by the authors. In particular, a prescribed degree of stability is applied to provide a simple tuning parameter to the closed-loop performance.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.