Abstract

When contacts interrupt the current path to an inductive load, the resulting voltage surge produces effects that can be detrimental to performance of the system. The high and often oscillatory voltages can cause both radiation interference and voltage breakdown in the wiring, in associated components, or in the contact gaps themselves where the resulting arcs lead to contact erosion. Some general quantitative relationships between these voltages and the important parameters of the contact and of the local circuit are derived and discussed. The resulting equations are then applied specifically to the case where the load is an unprotected relay coil, with discussion of peak voltages, time to reach peak, and energy content that is available to be dissipated outside the coil terminals as, for example, in contact arcs. Experimental confirmation is also demonstrated.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.