Abstract

Objective: To evaluate the use of transperineal ultrasound in predicting the successfulness of vaginal delivery.
 Methods: This was a prospective study conducted at Karawang District Hospital during the period between March 2016 and May 2016. Inclusion criteria were term pregnancy, singleton live head presentation, and active phase of labor. Using transperineal ultrasound, fetal head perineum distance, and angle of progression within relaxation phase between contraction were being calculated.
 Results: There were 306 subjects who delivered vaginally. The cut off value for fetal head perineum distance as a predictor of vaginal delivery was 43.5 mm (sensitivity 91%, specificity 78%), with area under a curve of 82% (95% CI 69 - 95%, p < 0.01); while angle of progression is 107° (sensitivity 80 %, specificity 97%), with Area under curve is 96.4% (95% CI 87 - 99%, p < 0.01).
 Conclusion: Fetal head perineum distance and angle of progression can predict the successfulness of vaginal delivery.
 [Indones J Obstet Gynecol 2017; 5-3: 149-153]
 Keywords: angle of progression, fetal head-perineum distance, prediction of vaginal delivery, transperineal ultrasound

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.