Abstract

This article presents a study of the use of transfer functions to predict vibrations inside a building due to train-induced ground vibrations. It is proposed that knowing the transfer function of a building, the vibrations inside a similar building can be predicted given a known ground motion outside. A comparison has been conducted between predicted and measured vibrations inside a building in south-western Sweden due to freight and passenger trains. The transfer function was derived by using a stationary vibrating source. The average particle velocity (1 s-r.m.s.) inside the house was calculated with the transfer functions with an average error of −10%, −0.02 mm/s. Prediction was achieved with a standard deviation of 23%, 0.06 mm/s when no filtering of the data was used. Further work is needed to ascertain the accuracy of this method.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.