Abstract

A novel atomic-contribution system for predicting of R M values is presented and validated on 13 thin layer chromatography screening systems on silica gel, where the large experimental datasets (198–761 R M values) are available. The R M is predicted with error less than 0.5 in majority of solutes (besides several outliers), which corresponds to difference in R F equal to 0.28 in the worst case. The system was validated by dividing the data into training and validation datasets, proving its accuracy. The main reason of larger errors in outliers are: large conjugated heterocycles, quarternary ammonium cations, large amount of polar atoms or very simple but unique molecules. The calculations are very easy and can be performed on free software or even manually. The presented method can be used in the retention prediction of new solutes in existing chromatographic screening systems.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.