Abstract

The responses of adjoining structures to blast induced ground vibrations emanating from Kopek Construction Quarry, Ikere – Ekiti in Ekiti State were evaluated and predicted. Five off site receptors at predetermined distances from the blast source were chosen and the Peak Particle Velocity (PPV) at each receptor during blasting was estimated using the squared root scaled distance equation. The estimated PPVs were compared with the USBM – RI 8705 reference. The results showed that the blast induced vibrations from the quarry site were within the recommended limits and were insignificant to warrant concerns of causing structural damages to buildings in proximity to the quarry site with the given blast design parameters.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.